WQS大流(liu)量潛(qian)水(shui)汙(wu)水(shui)泵
簡要(yao)描(miao)述:WQS大流(liu)量潛(qian)水(shui)汙(wu)水(shui)泵是我(wo)公(gong)司根據(ju)市(shi)場需(xu)要(yao)開(kai)發(fa)的(de)全新結(jie)構(gou)的壹(yi)種泵產品,*,國內該(gai)類型泵歷史(shi)空(kong)白(bai)。
產品型(xing)號(hao): 200WQS300-25-37-4
所(suo)屬(shu)分(fen)類:潛(qian)水(shui)排汙(wu)泵|無(wu)堵塞排(pai)汙(wu)泵廠(chang)家
更新(xin)時(shi)間:2024-10-19
廠(chang)商性(xing)質:生(sheng)產廠(chang)家
壹(yi)、WQS大流(liu)量潛(qian)水(shui)汙(wu)水(shui)泵概(gai)述(shu)
WQS大(da)型(xing)潛(qian)水(shui)排汙(wu)泵是我(wo)公(gong)司根據(ju)市(shi)場需(xu)要(yao)開(kai)發(fa)的(de)全新結(jie)構(gou)的壹(yi)種泵產品,*,國內該(gai)類型泵歷史(shi)空(kong)白(bai)。*解(jie)決了單(dan)吸(xi)式(shi)潛(qian)水(shui)電泵的軸(zhou)向拉力大(da),在(zai)較(jiao)高(gao)揚(yang)程(cheng)場合使(shi)用機(ji)械密(mi)封易漏水(shui)的缺點。因采用(yong)技(ji)術(shu)成(cheng)熟(shu)的單(dan)吸(xi)式(shi)潛(qian)水(shui)電泵的安裝結(jie)構(gou),即(ji)可(ke)以采用(yong)移動安裝,也(ye)可(ke)以(yi)采用(yong)導(dao)軌(gui)固(gu)定安裝. 安裝維(wei)護使(shi)用方(fang)便(bian)。在(zai)排(pai)送固(gu)體(ti)顆粒(li)和長纖維垃(la)圾方面,具(ju)有獨(du)*果(guo)。
該(gai)泵產品經(jing)測(ce)試各項性(xing)能指(zhi)標達到有關(guan)標準(zhun)規定,產品投(tou)放市(shi)場後以其*的功(gong)效(xiao),可(ke)靠(kao)的性(xing)能,穩定的(de)質(zhi)量受(shou)到廣大(da)用戶(hu)的(de)歡迎和好(hao)評(ping)。該(gai)泵分(fen)清水(shui)與汙(wu)水(shui)兩大(da)系(xi)列(lie), 同時(shi)這(zhe)兩大(da)系列(lie)內又分(fen)為(wei)普(pu)通型和帶外循(xun)環冷(leng)卻水(shui)型及自(zi)動攪勻(yun)型三(san)大類。
二、WQS大流(liu)量潛(qian)水(shui)汙(wu)水(shui)泵產品特點
1,該(gai)系列(lie)大型(xing)排汙(wu)泵,屬於(yu)壹(yi)種潛(qian)水(shui)電機(ji)為(wei)雙(shuang)吸(xi)式(shi)泵的巧妙組合(he),使(shi)其不僅具(ju)有潛(qian)水(shui)電泵的功(gong)能(neng),又(you)具(ju)有雙(shuang)吸(xi)泵高(gao)效運行(xing)平(ping)穩的特殊性(xing)能。
2,大(da)型(xing)潛(qian)水(shui)電泵可以(yi)達到較(jiao)高(gao)揚(yang)程(cheng)場合使(shi)用的(de)要求,因機械(xie)密(mi)封件處於(yu)負(fu)壓(ya)狀(zhuang)態(tai)運行,具(ju)有更高(gao)的穩定性(xing)。
3,采用(yong)雙(shuang)下吸(xi)水(shui)結(jie)構(gou)吸(xi)水(shui)位(wei)低,因采用(yong)雙(shuang)吸(xi)式(shi)雙(shuang)流(liu)道(dao)單(dan)蝸殼(ke)結(jie)構(gou),電機沒有了軸(zhou)向拉力,減(jian)輕(qing)並平衡了徑向力(li),大大提高(gao)了泵的使(shi)用壽命3倍,提高(gao)了使(shi)用效(xiao)率15%
4,配置外循(xun)環水(shui)裝置的泵,可以(yi)在(zai)低(di)水(shui)位(wei)場合連(lian)續(xu)長時(shi)間(jian)工(gong)作(zuo).配置自(zi)攪勻(yun)葉輪(lun)的泵,具(ju)有自(zi)攪勻(yun)功(gong)能(neng). 可(ke)以(yi)攪動水(shui)池內水(shui),使(shi)汙(wu)水(shui)汙(wu)物(wu)混(hun)合(he)隨(sui)泵排出(chu)。
5,WQS型(xing)采用(yong)大(da)流(liu)道(dao)抗(kang)堵(du)塞部件(jian)設(she)計(ji),大(da)大提高(gao)汙(wu)物(wu)通過能力(li),能(neng)有效(xiao)地(di)通過較短(duan)纖維物(wu)質和(he)直(zhi)徑較少的(de)固(gu)體(ti)顆粒(li)。
6,機械密(mi)封采用(yong)雙(shuang)道(dao)串(chuan)聯(lian)密(mi)封,材(cai)質(zhi)為硬(ying)質(zhi)耐(nai)腐碳化(hua)鎢,具(ju)有耐(nai)用(yong),耐磨等(deng)特點,可(ke)以(yi)使(shi)泵安全運(yun)行(xing)8000小時以上。
7,泵油室(shi)內設(she)有油(you)水(shui)探(tan)頭(tou),當水(shui)泵側(ce)機(ji)械密(mi)封(feng)損壞後,水(shui)進(jin)入(ru)油(you)室,探(tan)頭(tou)發生(sheng)信(xin)號(hao),對泵實施(shi)保護(hu)。
8,雙(shuang)導(dao)軌(gui)自(zi)動耦合(he)安全系(xi)統,給泵的安裝,維(wei)修帶(dai)來(lai)了極大(da)的方(fang)便(bian),人(ren)可不必為此(ci)需(xu)而(er)進(jin)出(chu)汙(wu)水(shui)坑。
9,浮(fu)球開關可根據(ju)所(suo)需(xu)的(de)水(shui)位(wei)變(bian)化(hua),自(zi)動控制(zhi)泵的停啟,無(wu)需(xu)專(zhuan)人(ren)看(kan)管。
10,根據(ju)使(shi)用場合電(dian)機(ji)可(ke)采用(yong)外循(xun)環冷(leng)卻系(xi)統,能保證(zheng)電(dian)泵在(zai)無(wu)水(shui)(幹式(shi))狀(zhuang)態下安全運(yun)行(xing)。
11,安裝方(fang)式有固(gu)定式(shi)自(zi)動耦合(he)安裝和(he)移動式安裝二(er)種,可(ke)滿(man)足(zu)不同的使(shi)用場合。
三(san),高(gao)效節能潛(qian)水(shui)排汙(wu)泵使(shi)用條件(jian)
1,介質(zhi)溫度不超(chao)過60℃,密度不超(chao)過1.3kg/L,PH值在(zai)5~9範圍內。
2,潛(qian)水(shui)泵無(wu)冷卻循(xun)環系(xi)統的,電機必須(xu)淹(yan)沒(mei)壹(yi)半以上,以免(mian)燒(shao)毀電(dian)機。
3,壹(yi)般(ban)情況下(xia),泵必須(xu)在(zai)使(shi)用揚(yang)程(cheng)範圍內使(shi)用,保證(zheng)電(dian)機不過載,如需(xu)在(zai)全(quan)揚(yang)程(cheng)範圍內使(shi)用,應(ying)在(zai)訂貨時(shi)另(ling)行註(zhu)明,以便(bian)廠(chang)家制(zhi)造(zao)。
4,實際使(shi)用揚(yang)程(cheng)必須(xu)和銘牌上(shang)所(suo)標註(zhu)的(de)揚(yang)程(cheng)相(xiang)近(jin),實際(ji)使(shi)用揚(yang)程(cheng)過低易(yi)超(chao)電(dian)流(liu)燒(shao)毀電(dian)機。
四(si)、WQS潛(qian)水(shui)汙(wu)水(shui)泵結(jie)構(gou)圖

五(wu)、參數(shu)表(biao)
序(xu)號(hao) | 型(xing)號(hao) | 流(liu)量m3/h | 揚(yang)程(cheng)m | 效率% | 功(gong)率kw | 轉速(su)r/min | 序(xu)號(hao) | 型(xing)號(hao) | 流(liu)量m3/h | 揚(yang)程(cheng)m | 效率% | 功(gong)率kw | 轉速(su) r/min |
1 | 100WQS80-10-4-4 | 80 | 10 | 68.1 | 4 | 1450 | 31 | 150WQS200-80-90-2 | 200 | 80 | 64.6 | 90 | 2900 |
2 | 100WQS100-12-5.5-4 | 100 | 12 | 71.3 | 5.5 | 1450 | 32 | 200WQS250-9-11-6 | 250 | 9 | 69.7 | 11 | 960 |
3 | 100WQS100-15-7.5-4 | 100 | 15 | 68.1 | 7.5 | 1450 | 33 | 200WQS250-12-15-6 | 250 | 12 | 68.1 | 15 | 960 |
4 | 100WQS100-20-11-4 | 100 | 20 | 66.1 | 11 | 1450 | 34 | 200WQS250-15-18.5-6 | 250 | 15 | 69.0 | 18.5 | 960 |
5 | 100WQS100-25-15-4 | 100 | 25 | 60.6 | 15 | 1450 | 35 | 200WQS250-20-22-4 | 250 | 20 | 71.9 | 22 | 1450 |
6 | 100WQS100-30-18.5-4 | 100 | 30 | 58.9 | 18.5 | 1450 | 36 | 200WQS250-25-30-4 | 250 | 25 | 66.8 | 30 | 1450 |
7 | 100WQS100-40-22-2 | 100 | 40 | 66.1 | 22 | 2900 | 37 | 200WQS250-32-37-4 | 250 | 32 | 69.3 | 37 | 1450 |
8 | 100VVQS100-50-30-2 | 100 | 50 | 60.6 | 30 | 2900 | 38 | 200WQS250-40-45-4 | 250 | 40 | 71.2 | 45 | 1450 |
9 | 100VVQS100-60-37-2 | 100 | 60 | 63.1 | 37 | 2900 | 39 | 200WQS250-45-55-4 | 250 | 45 | 69.7 | 55 | 1450 |
10 | 100WQS100-70-45-2 | 100 | 70 | 60.6 | 45 | 2900 | 40 | 200WQS250-55-75-4 | 250 | 55 | 62.4 | 75 | 1450 |
11 | 100WQS100-80-45-2 | 100 | 80 | 64.6 | 45 | 2900 | 41 | 200WQS250-65-90-4 | 250 | 65 | 65.6 | 90 | 1450 |
12 | 150WQS150-10-7.5-4 | 150 | 10 | 68.1 | 7.5 | 1450 | 42 | 200WQS300-7-11-6 | 300 | 7 | 69.4 | 11 | 960 |
13 | 150WQS150-15-11-4 | 150 | 15 | 69.7 | 11 | 1450 | 43 | 200WQS300-10-15-6 | 300 | 10 | 71.7 | 15 | 960 |
14 | 150WQS150-20-15-4 | 150 | 20 | 68.1 | 15 | 1450 | 44 | 200WQS300-12-18.5-6 | 300 | 12 | 70.7 | 18.5 | 960 |
15 | 150WQS150-25-18.5-4 | 150 | 25 | 69.0 | 18.5 | 1450 | 45 | 200WQS300-15-22-4 | 300 | 15 | 71.3 | 22 | 1450 |
16 | 150WQS150-30-22-4 | 150 | 30 | 69.7 | 22 | 1450 | 46 | 200WQS300-20-30-4 | 300 | 20 | 71.7 | 30 | 1450 |
17 | 150WQS150-35-30-4 | 150 | 35 | 63.6 | 30 | 1450 | 47 | 200WQS300-25-37-4 | 300 | 25 | 71.6 | 37 | 1450 |
18 | 150WQS150-40-37-2 | 150 | 40 | 63.1 | 37 | 2900 | 48 | 200WQS300-30-45-4 | 300 | 30 | 71.7 | 45 | 1450 |
19 | 150VVQS150-50-45-2 | 150 | 50 | 60.6 | 45 | 2900 | 49 | 200WQS300-40-55-4 | 300 | 40 | 72.3 | 55 | 1450 |
20 | 150WQS150-65-55-2 | 150 | 65 | 64.4 | 55 | 2900 | 50 | 200WQS300-50-75-4 | 300 | 50 | 68.1 | 75 | 1450 |
21 | 150WQS150-80-75-2 | 150 | 80 | 62.3 | 75 | 2900 | 51 | 200WQS300-55-75-4 | 300 | 55 | 72.9 | 75 | 1450 |
22 | 150WQS200-11-11-4 | 200 | 11 | 68.1 | 11 | 1450 | 52 | 200WQS300-60-90-4 | 300 | 60 | 68.1 | 90 | 1450 |
23 | 150WQS200-15-15-4 | 200 | 15 | 68.1 | 15 | 1450 | 53 | 200WQS350-8-15-6 | 350 | 8 | 63.6 | 15 | 960 |
24 | 150WQS200-18-18.5-4 | 200 | 18 | 66.3 | 18.5 | 1450 | 54 | 200WQS350-11-18.5-6 | 350 | 11 | 70.9 | 18.5 | 960 |
25 | 150WQS200-22-22-4 | 200 | 22 | 68.1 | 22 | 1450 | 55 | 200WQS350-13-22-6 | 350 | 13 | 70.4 | 22 | 960 |
26 | 150WQS200-27-30-4 | 200 | 27 | 65.4 | 30 | 1450 | 56 | 200WQS350-17-30-4 | 350 | 17 | 67.6 | 30 | 1450 |
27 | 150WQS200-32-37-4 | 200 | 32 | 62.8 | 37 | 1450 | 57 | 200WQS350-22-37-4 | 350 | 22 | 66.7 | 37 | 1450 |
28 | 150WQS200-40-45-2 | 200 | 40 | 64.6 | 45 | 2900 | 58 | 200WQS350-28-45-4 | 350 | 28 | 69.8 | 45 | 1450 |
29 | 150WQS200-50-55-2 | 200 | 50 | 66.1 | 55 | 2900 | 59 | 200WQS350-35-55-4 | 350 | 35 | 71.4 | 55 | 1450 |
30 | 150WQS200-65-75-2 | 200 | 65 | 63.0 | 75 | 2900 | 60 | 200WQS350-42-75-4 | 350 | 42 | 66.8 | 75 | 1450 |
使(shi)用說明
1、泵使(shi)用前應(ying)先(xian)閱讀說明書及泵上貼(tie)的(de)警告內容(rong),並仔(zai)細檢查電纜有否(fou)損壞,緊固(gu)件是(shi)否(fou)松動或(huo)脫(tuo)落,泵在(zai)運(yun)輸、存(cun)放、安裝過程(cheng)中有無(wu)變(bian)形或(huo)損壞。
2、用(yong)500V兆(zhao)歐表(biao)測(ce)量電(dian)動機相(xiang)同和(he)相(xiang)對地(di)間(jian)絕(jue)緣電(dian)阻,其(qi)值應(ying)不低於(yu)50兆(zhao)歐(ou),否(fou)則應對電機(ji)定子繞(rao)組進(jin)行(xing)幹燥(zao)處理(li),幹燥(zao)處理(li)的溫度不允(yun)許超(chao)過120℃。
3、該(gai)系列(lie)泵的安裝有固(gu)定式(shi)和(he)移動式兩(liang)種。當(dang)采用(yong)固(gu)定式(shi)自(zi)動安裝時(shi),應將(jiang)鏈索分(fen)別穿(chuan)進(jin)(偏(pian)離泵出水(shui)口(kou),其(qi)連線(xian)應平(ping)行(xing)於(yu)泵出水(shui)口(kou)的(de))兩個(ge)吊環(huan)螺釘或(huo)起(qi)吊板中(zhong)上(shang)下起(qi)吊電(dian)泵。均勻緩慢地(di)沿(yan)導(dao)軌(gui)下(xia)滑,直(zhi)到自(zi)動耦合(he)到位(wei)。當采用(yong)移動式安裝時(shi),先(xian)將(jiang)軟管套好(hao),用(yong)鏈索穿(chuan)進(jin)兩(liang)個吊環(huan)上起(qi)吊電(dian)泵,註(zhu)意(yi)不能將(jiang)電纜(lan)當(dang)作(zuo)繩索使(shi)用,以(yi)免(mian)使(shi)電纜(lan)頭(tou)松動漏水(shui)而發(fa)生(sheng)危(wei)險。
4、泵接通後的旋轉方(fang)向從(cong)進(jin)水(shui)口(kou)看(kan)為逆(ni)時針(zhen)轉動。如果(guo)電(dian)泵反轉(zhuan),只(zhi)需(xu)將(jiang)電纜(lan)中(zhong)的(de)任(ren)何二根線(xian)對調壹(yi)下接線(xian)位(wei)置即(ji)可(ke)。
5、電泵的(黃綠(lv)雙(shuang)色(se))接地(di)線(xian)必須(xu)嚴格按有關(guan)規(gui)程(cheng)接妥(tuo),為(wei)了保證(zheng)使(shi)用時(shi)的人(ren)身安全,在(zai)電(dian)泵運行(xing)時(shi),嚴禁在(zai)附(fu)近(jin)安裝人(ren)下水(shui)做事或(huo)移動,以防(fang)萬壹(yi)因在(zai)電(dian)泵漏電而(er)發生(sheng)意外事故(gu)。
6、電(dian)泵在(zai)無(wu)特殊情(qing)況必(bi)須(xu)配備全自(zi)動水(shui)泵控制(zhi)櫃及過載保護(hu)裝置,低要(yao)求應配置過載保護(hu)及漏電保護(hu)裝置。切勿(wu)直(zhi)接掛(gua)電(dian)網或(huo)使(shi)用閘刀開關來(lai)接通電源,確(que)保電(dian)泵正常(chang)運行(xing)。
7、不得將(jiang)電泵處於(yu)低(di)揚(yang)程(cheng)狀態(tai)下運行(壹(yi)般(ban)情況揚(yang)程(cheng)不得低於(yu)額(e)定揚(yang)程(cheng)的7 0%),能(neng)控制(zhi)
在(zai)建(jian)議使(shi)用揚(yang)程(cheng)範圍以(yi)內,以防(fang)電(dian)泵因超(chao)載而燒(shao)壞(huai)電機(ji)。
8、無(wu)自(zi)循(xun)環冷(leng)卻裝置的泵嚴禁整體(ti)露(lu)出(chu)水(shui)面運(yun)行(xing),電機部分(fen)露(lu)出(chu)液(ye)面(mian)不超(chao)過1/2,以防(fang)電(dian)泵過熱
維護(hu)保養(yang)
1、電(dian)泵應有專(zhuan)人(ren)管理(li)與使(shi)用,並定期(qi)檢查電泵繞組與機殼之間(jian)的(de)絕(jue)緣電(dian)阻是(shi)否(fou)正常(chang)。
2、每次(ci)使(shi)用特別是用(yong)於(yu)較(jiao)稠(chou)較粘(zhan)的(de)漿(jiang)液(ye)後,應將(jiang)電泵放入(ru)清水(shui)中運(yun)轉(zhuan)數分(fen)鐘(zhong),防(fang)止(zhi)泵內留下沈(chen)積(ji)物(wu),保證(zheng)電(dian)泵的清潔。
3、電泵加長時(shi)間(jian)不用時應(ying)將(jiang)電泵從(cong)水(shui)中取(qu)出(chu),不要浸泡(pao)在(zai)水(shui)中,以(yi)減(jian)少電(dian)機(ji)定子繞(rao)組受(shou)潮(chao)的機(ji)會,增加(jia)電(dian)泵的使(shi)用壽命。
4、在(zai)常(chang)規狀(zhuang)態(tai)下泵每使(shi)用800~1000小時後應加註(zhu)或(huo)更換油(you)室(shi)中機(ji)油(you)(10~3 0號(hao)機(ji)油(you)),使(shi)機械(xie)密封(feng)保持(chi)良(liang)好(hao)的潤滑狀態(tai),提高(gao)機械密(mi)封(feng)的(de)使(shi)用壽命。
5、電泵拆卸(xie)、維(wei)修後,機殼組件(jian)必(bi)須(xu)經(jing)0.2 M P a氣(qi)密試驗檢查,以確保電(dian)機(ji)密(mi)封(feng)可靠(kao)。